{"product_id":"el1918-beckhoff-ethercat-terminal-8-channel-digital-input-24-v-dc-twinsafe-twinsafe-logic","title":"BECKHOFF EtherCAT Terminal, 8-channel digital input, 24 V DC, TwinSAFE, TwinSAFE Logic - EL1918","description":"\u003ch2\u003eBECKHOFF EtherCAT Terminal, 8-channel digital input, 24 V DC, TwinSAFE, TwinSAFE Logic - EL1918\u003c\/h2\u003e\n\u003cp\u003eThe EtherCAT terminal has eight fail-safe inputs, which are transmitted via FSoE to a TwinSAFE Logic-capable component. The EL1918 has safety parameters to specifically adapt the functionality to the respective safety requirements. Thus, for example, test pulses can be configured with fine granularity for all eight channels in order to be able to connect as many types of sensors as possible.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-6v43{background-color:#ffffff;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-y0hg{background-color:#ffffff;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eCondition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-y0hg\"\u003eNew \/ Never Used Surplus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eBECKHOFF\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eEL1918\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eConnection technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003e1-\/2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eNumber of inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eTwinSAFE\/Safety over EtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eFault response time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003e≤ watchdog time (parameterizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eCurrent consumption E-bus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003etyp. 165 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eInstallation position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003ehorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eIP protection rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eDesign form\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eHD (High Density) housing with signal LEDs\u003cbr\u003eMaterial polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eDimensions (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eon 35 mm DIN rail, conforming to EN 60715 with lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eSide by side mounting by means of\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003edouble slot and key connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eMarking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003elabeling of the BZxxx series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eWiring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003esolid conductors (s): direct plug-in technique; fine-stranded conductors (st) and ferrule (f): spring actuation by screwdriver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eConnection cross-section\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003es*: 0.08…1.5 mm²,\u003cbr\u003est*: 0.25…1.5 mm²,\u003cbr\u003ef*: 0.14…0.75 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eConnection cross-section AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003es*: AWG 28…16,\u003cbr\u003est*: AWG 22…16,\u003cbr\u003ef*: AWG 26…19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eStripping length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003e8…9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-6v43\"\u003e\u003cspan style=\"font-weight: 500;\"\u003eCurrent load power contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-y0hg\"\u003eImax: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About EL1918\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sheets-userformat='{\"2\":707,\"3\":{\"1\":0},\"4\":{\"1\":2,\"2\":14281427},\"9\":1,\"10\":1,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"The EL1918 TwinSAFE component is a digital input terminal for sensors with potential-free contacts for 24 V DC. The EtherCAT terminal has eight fail-safe inputs, which are transmitted via FSoE to a TwinSAFE Logic-capable component.\\n\\nThe EL1918 has safety parameters to specifically adapt the functionality to the respective safety requirements. Thus, for example, test pulses can be configured with fine granularity for all eight channels in order to be able to connect as many types of sensors as possible.\\n\\nThe safety parameters are not stored directly on the component, but are transmitted to the input terminal via a TwinSAFE Logic-capable component when the safety application is started. This simplifies service procedures, because the component can simply be replaced. The safety-relevant parameters are transferred to the new component when the safety application is restarted.\\n\\nA further highlight of the EL1918 is the integration of the functionality of the EL6910 TwinSAFE Logic. The EL1918 can also be used as a safety controller at any time. In the default case, the EL1918 is a simple input terminal, whose input signals are transmitted via FSoE to a TwinSAFE Logic-capable component. It can be used directly as a safety controller in order to process input signals directly in the terminal so as to forward only accumulated information to a TwinSAFE Logic, or a complete safety application can be implemented on the EL1918. The range of functions corresponds to that of the EL6910. The only difference is the limitation of the number of possible safe connections to 128. Apart from that, all the advantages of the new generation of safety controllers can be used (see EL6910 customizing, incremental download, analog value processing, etc.).\\n\\nSpecial features EL1918:\\n\\n8 safe inputs\\nintegrated TwinSAFE Logic (functionality similar to the EL6910)\\nup to 128 safe connections\\nfine granular configuration of the test pulses of the individual channels\\nFor applications without integrated TwinSAFE Logic, the EL1918-2200 can be used.\\n\\nSpecial features EL1918-2200:\\n\\n8 safe inputs\\nfine granular configuration of the test pulses of the individual channels\\nTwinSAFE Logic not integrated\"}' data-sheets-root=\"1\"\u003eThe safety parameters are not stored directly on the component, but are transmitted to the input terminal via a TwinSAFE Logic-capable component when the safety application is started. This simplifies service procedures, because the component can simply be replaced. The safety-relevant parameters are transferred to the new component when the safety application is restarted.\u003cbr\u003e\u003cbr\u003eA further highlight of the EL1918 is the integration of the functionality of the EL6910 TwinSAFE Logic. The EL1918 can also be used as a safety controller at any time. In the default case, the EL1918 is a simple input terminal, whose input signals are transmitted via FSoE to a TwinSAFE Logic-capable component. It can be used directly as a safety controller in order to process input signals directly in the terminal so as to forward only accumulated information to a TwinSAFE Logic, or a complete safety application can be implemented on the EL1918. The range of functions corresponds to that of the EL6910. The only difference is the limitation of the number of possible safe connections to 128. Apart from that, all the advantages of the new generation of safety controllers can be used (see EL6910 customizing, incremental download, analog value processing, etc.).\u003cbr\u003e\u003cbr\u003eSpecial features EL1918:\u003cbr\u003e\u003cbr\u003e8 safe inputs\u003cbr\u003eintegrated TwinSAFE Logic (functionality similar to the EL6910)\u003cbr\u003eup to 128 safe connections\u003cbr\u003efine granular configuration of the test pulses of the individual channels\u003cbr\u003eFor applications without integrated TwinSAFE Logic, the EL1918-2200 can be used.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer information\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eBeckhoff\u003c\/strong\u003e Automation is a German manufacturer of open automation systems, including industrial PCs, I\/O and fieldbus components, drive technology, automation software, and hardware for machine vision. Beckhoff is known for its innovative and reliable automation technology, which is used in a wide range of industries. The company is committed to providing customers with the best possible automation solutions to help them succeed in their businesses.\u003c\/p\u003e\n\u003ch5 data-start=\"82\" data-end=\"108\"\u003e\u003cstrong data-start=\"82\" data-end=\"108\"\u003eWhat Our Experts Think\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul data-start=\"110\" data-end=\"691\"\u003e\n\u003cli data-start=\"110\" data-end=\"235\" class=\"\"\u003e\n\u003cp data-start=\"112\" data-end=\"235\" class=\"\"\u003eHigh Performance: Beckhoff control systems offer powerful computing capabilities for demanding industrial automation tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"236\" data-end=\"338\" class=\"\"\u003e\n\u003cp data-start=\"238\" data-end=\"338\" class=\"\"\u003eEnergy-Efficient: Designed with optimized power usage to support sustainable, low-energy operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"339\" data-end=\"458\" class=\"\"\u003e\n\u003cp data-start=\"341\" data-end=\"458\" class=\"\"\u003eDurable \u0026amp; Reliable: Built to withstand harsh industrial environments with high-quality components and rugged designs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"459\" data-end=\"575\" class=\"\"\u003e\n\u003cp data-start=\"461\" data-end=\"575\" class=\"\"\u003eQuiet Operation: Fanless or low-noise cooling systems in many models ensure minimal disruption in sensitive areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"576\" data-end=\"691\" class=\"\"\u003e\n\u003cp data-start=\"578\" data-end=\"691\" class=\"\"\u003eEasy Installation: Modular design allows for quick and flexible setup in a wide range of industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 data-start=\"693\" data-end=\"700\"\u003e\u003cstrong data-start=\"693\" data-end=\"700\"\u003eQ\u0026amp;A\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp data-start=\"702\" data-end=\"888\" class=\"\"\u003e\u003cstrong data-start=\"702\" data-end=\"745\"\u003eQ: What is Beckhoff equipment used for?\u003c\/strong\u003e\u003cbr data-start=\"745\" data-end=\"748\"\u003eA: Beckhoff products are used for industrial automation, providing control, motion, and communication solutions for a variety of industries.\u003c\/p\u003e\n\u003cp data-start=\"890\" data-end=\"1117\" class=\"\"\u003e\u003cstrong data-start=\"890\" data-end=\"955\"\u003eQ: What features are included in Beckhoff automation systems?\u003c\/strong\u003e\u003cbr data-start=\"955\" data-end=\"958\"\u003eA: Features include high-performance CPUs, modular I\/O systems, compact form factors, and support for leading industrial communication standards like EtherCAT.\u003c\/p\u003e\n\u003cp data-start=\"1119\" data-end=\"1286\" class=\"\"\u003e\u003cstrong data-start=\"1119\" data-end=\"1165\"\u003eQ: Are Beckhoff products energy-efficient?\u003c\/strong\u003e\u003cbr data-start=\"1165\" data-end=\"1168\"\u003eA: Yes, many Beckhoff systems are designed to reduce energy consumption while maintaining high-speed, precise control.\u003c\/p\u003e\n\u003cp data-start=\"1288\" data-end=\"1498\" class=\"\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1348\"\u003eQ: How does Beckhoff compare to other automation brands?\u003c\/strong\u003e\u003cbr data-start=\"1348\" data-end=\"1351\"\u003eA: Beckhoff stands out for its open automation systems, flexible designs, and strong performance in both small and large-scale industrial projects.\u003c\/p\u003e\n\u003ch5 data-start=\"1500\" data-end=\"1520\"\u003e\u003cstrong data-start=\"1500\" data-end=\"1520\"\u003eMaintenance Tips\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul data-start=\"1522\" data-end=\"2020\"\u003e\n\u003cli data-start=\"1522\" data-end=\"1614\" class=\"\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1614\" class=\"\"\u003eKeep Units Clean: Regularly remove dust and debris from ventilation openings and surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1615\" data-end=\"1698\" class=\"\"\u003e\n\u003cp data-start=\"1617\" data-end=\"1698\" class=\"\"\u003eCheck Connections: Inspect cables and connectors periodically for wear or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1699\" data-end=\"1805\" class=\"\"\u003e\n\u003cp data-start=\"1701\" data-end=\"1805\" class=\"\"\u003eMonitor Software Updates: Keep firmware and software updated to ensure optimal performance and security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1806\" data-end=\"1916\" class=\"\"\u003e\n\u003cp data-start=\"1808\" data-end=\"1916\" class=\"\"\u003eTemperature Control: Ensure devices are operated within recommended temperature ranges to avoid overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1917\" data-end=\"2020\" class=\"\"\u003e\n\u003cp data-start=\"1919\" data-end=\"2020\" class=\"\"\u003eAnnual System Check: Have a technician perform a full inspection and preventive maintenance annually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":45456191389756,"sku":"EL1918","price":668.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/6151\/5324\/files\/el1918__web_preview_png.webp?v=1780290139","url":"https:\/\/e-powergo.com\/products\/el1918-beckhoff-ethercat-terminal-8-channel-digital-input-24-v-dc-twinsafe-twinsafe-logic","provider":"Set Up Your Ultimate Retreat","version":"1.0","type":"link"}