{"product_id":"hpc-36-square-flat-pan-torpedo-burner-electronic-ignition-system","title":"Hearth Products Controls HPC 36″ Square Flat Pan Torpedo Burner Electronic Ignition System -  TOR-36FSSEI-SQ-120VAC","description":"\u003ch2\u003e\u003cb\u003eHearth Products Controls HPC 36″ Square Flat Pan Torpedo Burner Electronic Ignition System -  TOR-36FSSEI-SQ-120VAC\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cb\u003eIntroducing our Electronic Ignition Kits\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThese HPC Square Flat Pan Torpedo Burner Electronic Ignition Fire Pit insert kits comprise: \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSquare Flat Pan fitted with a Torpedo Penta Burner\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eElectronic Ignition system mounted to the underside of the fire pit pan\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe system is also available with a standard Penta Burner\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe complete system is fully assembled and ready for installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFitted with the Torpedo Burner, the On\/Off version is available in six sizes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eHi\/Lo units are available in four sizes.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cb\u003eHow It Works\u003c\/b\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eStart-Up:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e This is done by use of a wall switch or remote control. The system completes initial safety checks and starts the pilot gas flow when the ON command is received. After 5 seconds the hot surface igniter glows igniting the pilot flame. When the system confirms pilot flame present, the main burner gas will flow ignited by the pilot flame. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eOperation:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e While enjoying the ambiance of your fire pit, the system is at work monitoring flame status, internal temperatures\/voltages and other safety parameters. If flame loss does occur, the system will turn off all gas flow, and then restart by automatically commencing Start sequence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eShut Down:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e To turn OFF the fire pit simply use wall switch, remote control or whole house system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch5\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFully Assembled- ready to install. Control components are protected within valve box.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eStart via wall switch, remote or whole house system; auto re-light if flame is lost.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIgnition is complete using a robust and reliable Hot Surface igniter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOn\/Off models: Use optional wall switch or Remote Control available.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh\/Low Flame Control Models: Adjust high setting to low setting- ~45% turn down (Remote Control included).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e120vac: Standard outdoor grounded power cord- simply plug into GFCI outlet.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e24vac Option: Typically used poolside or with other lower voltage requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNatural Gas or Liquid Propane: Factory built \u0026amp; tested for either fuel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eInternal temperature monitoring with overheat auto shutoff.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Certified in US \u0026amp; Canada to ANSI Z21.97-2014 \/ CSA 2.41-2014 requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOptional Controls: On\/Off Remote, Timers, Power Supplies and an Emergency Shutoff.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOn\/Off Models:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e Includes the convenience and safety features- optional remote control available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHigh \/ Low Flame Control Models:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e This option includes a smart remote control with 2-way communication with the fire pit. Remote allows flame height control while receiving information from fire pit to advise user of fire pit status (flashing LED).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cstrong\u003eWhat Our Experts Think\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e36-Inch Square Flat Pan Design:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e The Hearth Products Controls TOR-36FSSEI-SQ-120VAC features a 36-inch square flat fire pit pan designed for compatible outdoor gas fire pit installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Performance Torpedo Penta Burner:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Equipped with HPC's Torpedo Penta Burner, designed to create a distinctive flame display across the square fire pit surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdvanced Hot Surface Electronic Ignition:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Uses a hot surface igniter to ignite the pilot flame before automatically allowing gas to flow to the main burner.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAutomatic Flame Monitoring and Relight:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Continuously monitors flame conditions and automatically shuts off gas flow if flame loss occurs before initiating a restart sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Safety Protection:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Features internal temperature and voltage monitoring, electronic safety checks, and automatic overheat shutoff for controlled operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFully Assembled Fire Pit Insert:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Includes the square flat pan, Torpedo Penta Burner, electronic ignition assembly, and protected valve box, supplied fully assembled for installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e120VAC Electrical Configuration:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Operates using a standard outdoor grounded power cord connected to a suitable GFCI-protected electrical outlet, with natural gas and propane versions available within the product range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCSA-Certified Electronic Ignition System:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e The manufacturer states certification in the United States and Canada to ANSI Z21.97-2014\/CSA 2.41-2014 requirements, with optional remote controls and additional accessories available depending on the configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cstrong\u003eQ\u0026amp;A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the Hearth Products Controls 36-Inch Square Flat Pan Torpedo Burner Electronic Ignition System?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: It is a fully assembled outdoor gas fire pit insert featuring a 36-inch square flat pan, Torpedo Penta Burner, and electronically controlled ignition system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the model number of this fire pit system?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: The model number is TOR-36FSSEI-SQ-120VAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What size is the fire pit insert?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: The system features a 36-inch square flat burner pan.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of burner is included?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: It includes an HPC Torpedo Penta Burner designed to produce a distinctive outdoor flame display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of ignition system does this model use?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: It uses electronic ignition with a hot surface igniter, pilot flame verification, and automatic main burner ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does the electronic ignition system start?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: When an ON command is received, the system performs safety checks, begins pilot gas flow, and activates the hot surface igniter after approximately five seconds. Once the pilot flame is confirmed, the main burner ignites.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the system automatically relight if the flame goes out?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: Yes. If flame loss is detected, the system shuts off gas flow and automatically begins its restart sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What electrical supply is required?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: This model requires a 120VAC electrical supply and is designed to connect to a suitable GFCI-protected outlet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What fuel types are available?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: The manufacturer offers factory-built and tested natural gas and liquid propane configurations. The specific fuel type for this SKU should be confirmed before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is a 24VAC version available?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: Yes. The product range includes 24VAC configurations for installations requiring lower-voltage electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the fire pit be operated with a remote control?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: Remote control options are available. On\/Off configurations offer optional remote control, while High\/Low configurations include a compatible smart remote.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does this model provide adjustable flame height?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: High\/Low flame adjustment is available on designated High\/Low models, with approximately 45% turndown. The supplied specifications do not confirm that this particular SKU includes High\/Low functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What safety features are included?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: The system includes flame sensing, automatic gas shutoff following flame loss, automatic relight, internal temperature monitoring, voltage monitoring, and overheat protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this electronic ignition system CSA certified?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eA: The manufacturer states that the system is CSA certified in the United States and Canada to ANSI Z21.97-2014\/CSA 2.41-2014 requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance Tips\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eClean the Square Flat Pan:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Allow the fire pit to cool completely before removing dust, leaves, and debris from the burner pan.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInspect the Torpedo Penta Burner:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Periodically check the burner for obstructions, corrosion, or visible damage that could affect flame performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaintain the Hot Surface Igniter:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Keep the ignition area free from debris and have damaged or malfunctioning ignition components serviced by a qualified technician.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCheck the Pilot Assembly:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Have the pilot assembly inspected if ignition becomes unreliable or the system repeatedly attempts to relight.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInspect Flame-Sensing Components:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Arrange periodic inspection of the flame-monitoring system to ensure proper operation and safety response.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtect the Electronic Valve Box:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Ensure the control enclosure remains properly installed and protected according to the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInspect Electrical Connections:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Check accessible power connections for visible damage and have electrical faults evaluated by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaintain the GFCI-Protected Power Supply:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Ensure the system remains connected to a suitable grounded, GFCI-protected electrical outlet and follow the outlet manufacturer's testing instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeep Ventilation Openings Clear:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Maintain all required enclosure ventilation and installation clearances to prevent overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInspect Gas Connections:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Have gas lines, fittings, and connections periodically inspected by a qualified gas technician. Never use an open flame to check for leaks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSchedule Professional Servicing:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Arrange qualified inspection if ignition failures, repeated shutdowns, irregular flames, electrical problems, or other operating issues occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ePower Go","offers":[{"title":"Natural Gas","offer_id":52679311851815,"sku":"TOR-36FSSEI-SQ-120VAC","price":4936.2,"currency_code":"USD","in_stock":true},{"title":"Liquid Propane","offer_id":52679311884583,"sku":"TOR-36FSSEI-SQ-120VAC","price":4936.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0856\/8448\/6439\/files\/sSEGqd8M_d2c2af12-2fe1-4324-933e-80158b02b942.jpg?v=1795283629","url":"https:\/\/e-powergo.com\/products\/hpc-36-square-flat-pan-torpedo-burner-electronic-ignition-system","provider":"ePower Go","version":"1.0","type":"link"}