Discover How Our Flame-Sensing Battery Spark Works

  1. Start-Up: This is done by simultaneously pressing valve control knob to start flow of pilot gas and pressing ignition button for spark. Release spark after pilot ignition, release valve control knob after ~20 seconds. Then turn valve control knob counterclockwise to light main burner.
  2. Operation: Flame height may be adjusted by turning valve control knob- counterclockwise provides more flame, clockwise lowers flame. If flame loss does occur, the system will automatically turn off all gas flow. 
  3. Shut Down: To turn OFF the fire pit simply turn valve control knob clockwise- slightly depress knob to reach OFF position.
Features
  • Fully Assembled and ready to install. Control components are protected within valve box.
  • Flex Line configuration provides versatile and simple installation.
  • Start ignition with push button and valve control knob.
  • The flame sensing system will turn off gas if flame is lost.
  • Flame height is adjustable using valve control knob.
  • Battery Operated System is the perfect solution for installs with no power.
  • Natural Gas or Liquid Propane: Factory built & tested for either fuel.
  • CSA Certified in US & Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.
  • Optional Install: Control Box Sleeve for mounting in pavers, metal, and more.
  • Complete drop-in fire pit insert utilizes a standing pilot with thermocouple to safely control gas flow, manual spark igniter (AA battery), and safety pilot valve.
  • Up to 140,000 BTU
  • Comes fully assembled with #304 stainless steel pan & burner, FPPK-HC control box with pilot assembly, and whistle-free flex line.
  • CSA Certified Small Tank Approved with use of STLPK Kit if shown with this symbol (*ST*)
What Our Experts Think
  • 18-Inch Square Drop-In Design: The kit provides a square insert configuration for a compatible fire pit enclosure.
  • Natural Gas Version: Model FPPK18-SQBL-FLEX-NG identifies the natural gas configuration.
  • 304 Stainless Steel Components: The supplied pan and burner are made from #304 stainless steel.
  • Battery Spark Ignition: The manual spark igniter uses an AA battery, supporting installations without household electrical power.
  • Flame-Sensing Gas Control: A standing pilot, thermocouple, and safety pilot valve control gas flow and shut it off if flame is lost.
  • Adjustable Flame Height: The valve control knob allows manual flame adjustment.
  • Up to 140,000 BTU: The listed maximum heat input is up to 140,000 BTU; installation must follow the exact model’s requirements.
  • Assembled Package: Includes the pan, burner, FPPK-HC control box with pilot assembly, and whistle-free flex line. The mounting sleeve is optional.
Q&A

Q: What is the product model?
A: This is the Hearth Products Controls 18″ Square Drop-In Manual Spark Ignition Kit, model FPPK18-SQBL-FLEX-NG.

Q: Which fuel is this version intended for?
A: The NG model designation identifies the natural gas version. Confirm the fuel label before installation.

Q: Can this natural gas kit also use propane?
A: The product line offers factory-built versions for either fuel. This does not establish that the NG unit can use propane without manufacturer-approved changes.

Q: What are the pan and burner made from?
A: Both are specified as #304 stainless steel.

Q: What heat input is listed?
A: The description lists up to 140,000 BTU.

Q: How is ignition operated?
A: Ignition uses a push button and valve control knob to establish the pilot before lighting the main burner. Follow the complete lighting instructions supplied with the unit.

Q: What battery does the igniter use?
A: The manual spark igniter uses an AA battery. Battery inclusion is not specified.

Q: Does the system require household electricity?
A: The ignition system is battery operated and described for installations without supplied electrical power.

Q: How does flame sensing work?
A: The standing pilot and thermocouple work with the safety pilot valve to control gas flow. The system shuts off gas if flame is lost.

Q: Is flame height adjustable?
A: Yes. The supplied instructions state that counterclockwise knob movement increases flame and clockwise movement reduces it.

Q: What comes assembled with the kit?
A: The listed package includes the stainless steel pan and burner, FPPK-HC control box with pilot assembly, and whistle-free flex line.

Q: Is the control box sleeve included?
A: No sleeve is listed as included. It is described as an optional mounting accessory.

Q: What certification is stated?
A: The supplied description states CSA certification in the US and Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.

Q: Is this specific model approved for a small propane tank?
A: The description makes approval conditional on an ST designation and use of the STLPK kit. That designation is not shown for this NG model, so small-tank suitability is not established.

Maintenance Tips
  • Shut Down Before Servicing: Turn off the burner and isolate the gas supply according to the manufacturer’s instructions.
  • Allow Complete Cooling: Let the pan, burner, and surrounding surfaces cool before handling.
  • Follow the Model Manual: Use the maintenance instructions specific to FPPK18-SQBL-FLEX-NG.
  • Maintain the Ignition Battery: Use the specified AA battery and follow replacement and polarity instructions.
  • Keep the Pilot Area Clear: Remove accessible debris around the pilot, thermocouple, and spark components only as directed.
  • Inspect Burner Openings: Check for blockages and use the approved cleaning method.
  • Clean Stainless Steel Properly: Use manufacturer-approved cleaners and avoid tools that damage the finish.
  • Protect the Control Box: Keep debris away and maintain required drainage, ventilation, and service access.
  • Inspect the Flex Line: Have damaged, kinked, or deteriorated gas connections assessed by a qualified technician.
  • Use Approved Leak Testing: Have gas connections checked using an approved procedure; never use a flame.
  • Service Abnormal Operation: Stop use and arrange qualified service if ignition, flame adjustment, or safety shutoff operates incorrectly.