Discover How Our Flame-Sensing Battery Spark Works

  1. Start-Up: This is done by simultaneously pressing valve control knob to start flow of pilot gas and pressing ignition button for spark. Release spark after pilot ignition, release valve control knob after ~20 seconds. Then turn valve control knob counterclockwise to light main burner.
  2. Operation: Flame height may be adjusted by turning valve control knob- counterclockwise provides more flame, clockwise lowers flame. If flame loss does occur, the system will automatically turn off all gas flow. 
  3. Shut Down: To turn OFF the fire pit simply turn valve control knob clockwise- slightly depress knob to reach OFF position.
Features
  • Fully Assembled and ready to install. Control components are protected within valve box.
  • Flex Line configuration provides versatile and simple installation.
  • Start ignition with push button and valve control knob.
  • The flame sensing system will turn off gas if flame is lost.
  • Flame height is adjustable using valve control knob.
  • Battery Operated System is the perfect solution for installs with no power.
  • Natural Gas or Liquid Propane: Factory built & tested for either fuel.
  • CSA Certified in US & Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.
  • Optional Install: Control Box Sleeve for mounting in pavers, metal, and more.
  • Complete drop-in fire pit insert utilizes a standing pilot with thermocouple to safely control gas flow, manual spark igniter (AA battery), and safety pilot valve.
  • Up to 140,000 BTU
  • Comes fully assembled with #304 stainless steel pan & burner, FPPK-HC control box with pilot assembly, and whistle-free flex line.
What Our Experts Think
  • 30-Inch Square Configuration: The title identifies a square drop-in insert; exact pan, burner, and cutout dimensions require confirmation.
  • Natural Gas Version: Model FPPK30-SQBL-FLEX-NG identifies the natural gas configuration.
  • 304 Stainless Steel Components: The supplied pan and burner are specified as #304 stainless steel.
  • AA Battery Spark Ignition: The manual spark igniter supports installations without household electrical power.
  • Flame-Sensing Shutoff: A standing pilot, thermocouple, and safety pilot valve control gas flow and shut it off if flame is lost.
  • Adjustable Flame Height: The valve control knob provides manual flame adjustment.
  • Up to 140,000 BTU: The description lists this maximum rating; confirm the exact unit’s nameplate and gas supply requirements.
  • Assembled Package: Includes the pan, burner, FPPK-HC control box with pilot assembly, and whistle-free flex line. The mounting sleeve is optional.
Q&A

Q: What is the product model?
A: This is the Hearth Products Controls 30″ Square Drop-In Manual Spark Ignition Kit, model FPPK30-SQBL-FLEX-NG.

Q: What does the 30-inch designation describe?
A: It is the size designation in the title. Detailed component and installation dimensions are not supplied.

Q: Which fuel does this version use?
A: The NG designation identifies the natural gas version. Confirm the unit’s fuel label before installation.

Q: Can this natural gas kit also use propane?
A: The product line offers factory-built versions for either fuel. Propane compatibility is not established for this NG unit.

Q: What are the pan and burner made from?
A: Both are specified as #304 stainless steel.

Q: What heat input is listed?
A: The description lists up to 140,000 BTU.

Q: How is ignition operated?
A: Startup uses the spark button and valve control knob to establish the pilot before lighting the main burner. Follow the complete lighting instructions supplied with the unit.

Q: What battery does the igniter use?
A: It uses an AA battery. Battery inclusion is not specified.

Q: Does the ignition system require household electricity?
A: No. The supplied description identifies a battery-operated ignition system.

Q: What happens if the flame goes out?
A: The flame-sensing system shuts off gas flow. Automatic relighting is not stated.

Q: Can flame height be adjusted?
A: Yes. The description states that counterclockwise knob movement increases flame and clockwise movement reduces it.

Q: What comes assembled with the kit?
A: The listed package includes the stainless steel pan and burner, FPPK-HC control box with pilot assembly, and whistle-free flex line.

Q: Is the control box sleeve included?
A: It is described as an optional installation accessory, not an included component.

Q: What certification and installation details are supplied?
A: The description states CSA certification in the US and Canada to ANSI Z21.97-2014 / CSA 2.41-2014. Gas pressure, clearances, ventilation, and mounting requirements must be obtained from the exact model’s installation manual.

Maintenance Tips
  • Shut Down Before Servicing: Turn off the system and isolate the gas supply according to the manual.
  • Allow Complete Cooling: Let the pan, burner, and surrounding surfaces cool before handling.
  • Follow Model Instructions: Use the maintenance procedures specific to FPPK30-SQBL-FLEX-NG.
  • Maintain the Ignition Battery: Use the specified AA battery and follow replacement and polarity instructions.
  • Keep the Pilot Area Clear: Remove accessible debris around the pilot, thermocouple, and igniter only as directed.
  • Inspect Burner Openings: Check for blockages without enlarging or modifying openings.
  • Clean Stainless Steel Properly: Use manufacturer-approved cleaners and tools that will not damage the finish.
  • Protect the Control Box: Maintain required drainage, ventilation, and service access.
  • Inspect the Flex Line: Have damaged, kinked, or deteriorated gas connections assessed by a qualified technician.
  • Use Approved Leak Testing: Have connections checked using an approved procedure; never test with a flame.
  • Service Abnormal Operation: Stop use and arrange qualified service if ignition, flame adjustment, or flame-sensing shutoff operates incorrectly.