Skip to product information
1 of 10

ePower Go

Hearth Products Controls 78″ X 16″ Rectangle Hot Surface Electronic Ignition System - 78X16SSEI-H-120VAC-NG

Hearth Products Controls 78″ X 16″ Rectangle Hot Surface Electronic Ignition System - 78X16SSEI-H-120VAC-NG

1 Review

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price Sale price $4,512.00
Shipping calculated at checkout.
Gas Type

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Hearth Products Controls 78″ X 16″ Rectangle Hot Surface Electronic Ignition System - 78X16SSEI-H-120VAC-NG

Introducing Our Electronic Ignition Kits

Enhance your fire pit experience with our 78″ X 16″ Rectangle Hot Surface Electronic Ignition System.

  1. Start Up: This is done by use of a wall switch or remote control. When the ON command is received, the system completes initial safety checks then starts flow of pilot gas. After 5 seconds the hot surface igniter glows igniting pilot flame. When the system confirms pilot flame present, the main burner gas will flow ignited by the pilot flame. 
  2. Operation: While enjoying the ambiance of your fire pit, the system is at work monitoring flame status, internal temperatures / voltages and other safety parameters. If flame loss does occur, the system will turn off all gas flow, and then restart by automatically commencing Start sequence.
  3. Shut Down: To turn OFF the fire pit simply use wall switch, remote control or whole house system.
Features:
  • Fully Assembled- ready to install. Control components are protected within valve box.
  • Start via wall switch, remote or whole house system; auto re-light if flame is lost.
  • Ignition is complete using a robust and reliable Hot Surface igniter.
  • On/Off models: Use with optional wall switch or Remote Control available.
  • High/Low Flame Control Models: Adjust high setting to low setting- ~45% turn down (Remote Control included).
  • 120vac: Standard outdoor grounded power cord- simply plug into GFCI outlet.
  • 24vac Option: Typically used pool side or with other lower voltage requirements.
  • Natural Gas or Liquid Propane: Factory built & tested for either fuel.
  • Internal temperature monitoring with overheat auto shutoff.
  • CSA Certified in US & Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.
  • Optional Controls: On/Off Remote, Timers, Power Supplies and an Emergency Shutoff.

On/Off Models: Includes the convenience and safety features- optional remote control available.
High / Low Flame Control Models: This option includes a smart remote control with 2-way communication with the fire pit. Remote allows flame height control while receiving information from fire pit to advise user of fire pit status (flashing LED).

What Our Experts Think
  • 78 × 16-Inch Configuration: The listed rectangular size identifies the system; enclosure and cutout dimensions require separate confirmation.
  • Natural Gas Version: Model 78X16SSEI-H-120VAC-NG identifies the natural gas configuration.
  • 120 VAC Power: This version uses an outdoor grounded power cord connected to a GFCI outlet.
  • Hot Surface Ignition: The system establishes and confirms pilot flame before supplying gas to the main burner.
  • Automatic Relighting: Flame loss triggers gas shutoff followed by an automatic startup sequence.
  • Internal Monitoring: The system monitors flame status, temperatures, voltages, and other operating parameters.
  • Overheat Shutoff: Internal temperature monitoring includes automatic shutdown if overheating occurs.
  • Assembled Controls: Components arrive protected within a valve box. High/low adjustment and remote inclusion are not confirmed for this SKU.
Q&A

Q: What is the product model?
A: The model is Hearth Products Controls 78X16SSEI-H-120VAC-NG.

Q: What size and shape are listed?
A: It is described as a 78 × 16-inch rectangular system. Required enclosure and cutout dimensions are not supplied.

Q: Which fuel does this version use?
A: The NG designation identifies the natural gas version. Confirm the unit’s fuel label before installation.

Q: Can this natural gas version use propane?
A: The product line offers factory-built versions for either fuel. Propane compatibility is not established for this NG unit.

Q: What electrical supply is specified?
A: This model specifies 120 VAC with an outdoor grounded power cord connected to a GFCI outlet.

Q: Is this the 24 VAC version?
A: No. The model specifies 120 VAC; 24 VAC is described as a separate option.

Q: How does ignition work?
A: After an ON command, the system performs safety checks, supplies pilot gas, and activates the hot surface igniter. Main burner gas flows after pilot flame confirmation.

Q: What happens if the flame goes out?
A: The system shuts off gas flow and automatically begins its startup sequence to attempt relighting.

Q: Does it provide overheat protection?
A: Yes. Internal temperature monitoring includes automatic overheat shutoff.

Q: How can it be turned on and off?
A: Suitable wall-switch, remote-control, or whole-house-system operation is described. Confirm the controls and interfaces required for this model.

Q: Does this SKU include high/low flame control?
A: High/low control is described as a separate configuration, but it is not confirmed for this SKU.

Q: Is a remote control included?
A: Remote inclusion is not confirmed. The description lists optional remotes for on/off models and included two-way remotes for high/low models.

Q: What certification is stated?
A: The supplied description states CSA certification in the US and Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.

Q: Are heat input, gas pressure, and installation clearances provided?
A: These specifications are not supplied. Follow the exact model’s installation manual and use qualified gas and electrical installation services.

Maintenance Tips
  • Isolate Before Servicing: Shut down the system and isolate gas and electrical supplies according to the manual.
  • Allow Complete Cooling: Let the burner and surrounding components cool before inspection or cleaning.
  • Prevent Automatic Restart: Follow the service procedure so remote commands or relighting cannot activate the system during maintenance.
  • Protect the Igniter: Avoid striking, bending, or handling the hot surface igniter except as instructed.
  • Keep the Pilot Area Clear: Remove accessible debris using the manufacturer-approved method.
  • Inspect Burner Openings: Check for obstructions without enlarging or modifying openings.
  • Maintain Valve Box Access: Keep required ventilation, drainage, and service access clear.
  • Inspect the Power Cord: Stop use if the cord, plug, or electrical connections show damage.
  • Follow GFCI Instructions: Test and maintain GFCI protection according to its manufacturer’s directions.
  • Arrange Qualified Gas Service: Have suspected leaks or damaged connections assessed using an approved procedure; never test with a flame.
  • Investigate Abnormal Operation: Arrange service for repeated ignition failures, unexpected shutdowns, or unusual flame behavior.