Skip to product information
1 of 11

ePower Go

Harvia Power Extension Unit - LTY45 U1-U3

Harvia Power Extension Unit - LTY45 U1-U3

1 Review

10% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $666.67 Sale price $600.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Harvia Power Extension Unit - LTY45 U1-U3

Harvia power extension unit LTY45 is used for the control of additional electric sauna heaters in large saunas. By using the power extension unit LTY45 the maximum load range can be increased up to 38 kW (the maximum load depends on the type of the control unit)

Includes
  • Power Unit

  • Installation and Operation Manual

  • Limited Warranty

Features
  • Works with Xenio CX30/45/170 Control Units
  • Increases max load range to 38kW
  • Can be wall-mounted
  • 14.3"W x 2.9"D x 10.5"H
Specifications
Model Xenio LTY45
Supply Voltage (Per extension box) 240 V 1Ph
Length 14.3" (364mm)
Width 2.9" (73mm)
Height 10.5" (267mm)
Weight 6.1lbs
What Our Experts Think
  • Advanced Sauna Power Extension Solution: The Harvia LTY45 U1-U3 Power Extension Unit is designed to expand the electrical load management capabilities of compatible sauna control systems in larger sauna installations.

  • Expanded Load Capacity Up to 38kW: Supports an increased maximum load range of up to 38kW, depending on the connected control unit and approved electrical configuration.

  • Dedicated Harvia Xenio Compatibility: Designed to work with compatible Harvia Xenio CX30, CX45, and CX170 control units, providing greater flexibility for high-capacity sauna heating systems.

  • Suitable for Large Sauna Installations: Provides a practical power management solution for larger residential and commercial saunas requiring additional electric heating capacity.

  • 240V Single-Phase Configuration: The supplied specifications identify a 240V single-phase electrical supply per extension box, supporting compatible electrical sauna heating configurations.

  • Convenient Wall-Mounted Installation: Features a wall-mountable design that allows organized installation in an appropriate location according to Harvia's electrical and environmental requirements.

  • Compact and Lightweight Construction: Measures approximately 14.3 inches wide, 2.9 inches deep, and 10.5 inches high, with a lightweight construction of 6.1 lbs.

  • Installation Documentation and Warranty Coverage: Includes an installation and operation manual together with limited warranty coverage, providing guidance for proper electrical integration and maintenance.

Q&A

Q: What is the Harvia LTY45 U1-U3 Power Extension Unit?

A: It is an electrical power extension unit designed to increase the maximum supported heating load of compatible Harvia Xenio sauna control systems, allowing additional electric sauna heating capacity in larger sauna installations.

Q: What is the manufacturer product number?

A: The supplied manufacturer product designation is LTY45 U1-U3, identifying the Harvia Xenio LTY45 Power Extension Unit.

Q: What is the maximum supported heating load of the Harvia LTY45?

A: The power extension unit supports an increased maximum system load range of up to 38kW (38,000 watts). The actual maximum supported load depends on the connected Xenio control unit, electrical supply, heater configuration, and manufacturer-approved installation arrangement.

Q: Which sauna control systems are compatible with the Harvia LTY45?

A: The power extension unit is designed to work with compatible Harvia Xenio CX30, CX45, and CX170 control units. Exact control unit versions, electrical configurations, and supported heating loads should be confirmed before purchasing.

Q: What electrical supply does the Harvia LTY45 require?

A: The supplied specifications list a 240V single-phase electrical supply per extension box. Although the product designation references U1-U3, a three-phase supply rating has not been provided. The exact electrical configuration, circuit breaker sizing, conductor requirements, and grounding must be verified by a qualified electrician.

Q: Is the Harvia LTY45 suitable for large commercial saunas?

A: The power extension unit is designed for larger sauna installations requiring additional electric heating capacity. It may be suitable for commercial and large residential sauna applications when integrated with compatible heating equipment and approved electrical configurations.

Q: Does the Harvia LTY45 generate heat independently?

A: No. The LTY45 is an electrical power extension accessory rather than a sauna heater. It expands the supported electrical load management capabilities of a compatible sauna control system and does not independently generate heat.

Q: Can the Harvia LTY45 operate without a Xenio control unit?

A: No. The power extension unit is designed to operate in conjunction with a compatible Harvia Xenio control unit. It is not a standalone sauna temperature controller or independent heating management system.

Q: Can the Harvia LTY45 control additional electric sauna heaters?

A: Yes. The power extension unit is designed to support additional electric sauna heating loads within compatible Harvia control configurations. The permitted number of heaters, individual heater capacities, and combined electrical load must comply with Harvia's installation requirements.

Q: What components are included with the Harvia LTY45?

A: The package includes the Harvia power extension unit, installation and operation manual, and limited warranty coverage. The external Xenio control unit, sauna heaters, electrical wiring, and additional installation accessories are not listed as included.

Q: How is the Harvia LTY45 power extension unit installed?

A: The power extension unit features a wall-mountable design and must be installed in a manufacturer-approved location. Electrical connections, mounting arrangements, environmental conditions, and ventilation requirements must follow Harvia's installation instructions and applicable electrical safety regulations.

Q: Does the Harvia LTY45 include Wi-Fi or smartphone control functionality?

A: The supplied product information does not identify independent Wi-Fi connectivity or smartphone control functionality. Remote sauna management depends on the capabilities of the connected Xenio control system and compliance with applicable remote-operation safety requirements.

Q: What are the overall product dimensions and weight?

A: The power extension unit measures approximately 14.3 inches wide × 2.9 inches deep × 10.5 inches high (364 × 73 × 267 mm) and weighs 6.1 lbs (2.77 kg). These measurements represent the individual power extension unit rather than the complete installed sauna control system.

Q: What are the shipping package dimensions and warranty details?

A: The Harvia LTY45 includes stated limited warranty coverage, although the exact warranty duration and consumer or commercial coverage conditions have not been specified. The product weight is 6.1 lbs (2.77 kg), excluding shipping materials. Exact shipping package width, height, depth, gross shipping weight, package count, country of manufacture, and safety certification details have not been provided.

Maintenance Tips
  • Clean Exterior Power Unit Surfaces: Regularly remove accumulated dust and dirt using a soft, dry cloth after safely disconnecting the electrical supply according to manufacturer instructions.

  • Inspect Power Unit Housing: Periodically examine the external housing for cracks, deformation, discoloration, corrosion, or physical damage that could indicate deterioration.

  • Maintain Proper Electrical Connections: Have a qualified electrician periodically inspect electrical terminals, wiring connections, grounding arrangements, and associated electrical components.

  • Verify Compatible Heating Loads: Ensure the connected sauna heaters and total electrical load remain within the manufacturer-approved limits of the power extension unit and associated Xenio control system.

  • Maintain Adequate Ventilation: Keep manufacturer-required ventilation openings and installation clearances unobstructed to support appropriate operating temperatures.

  • Inspect Wall-Mounting Components: Regularly examine accessible mounting hardware and supporting wall surfaces for looseness, corrosion, or physical deterioration that could affect installation stability.

  • Protect Against Excessive Moisture: Maintain the power extension unit in an approved installation environment and prevent exposure to water, condensation, and excessive humidity beyond manufacturer-specified limits.

  • Monitor Unusual Operating Conditions: Discontinue operation and arrange professional inspection if unusual noises, burning odors, excessive heat, or repeated electrical faults occur.

  • Maintain External Xenio Control Functionality: Periodically check the associated Xenio control unit for error messages, inconsistent operation, and heating management issues that may require professional servicing.

  • Avoid Unauthorized Electrical Modifications: Do not modify internal wiring, bypass electrical protection devices, or connect incompatible heating equipment without manufacturer approval.

  • Perform Scheduled Professional Servicing: Arrange periodic professional inspections of the power extension unit, electrical connections, circuit protection devices, associated control system, and connected sauna heaters to maintain safe and dependable long-term operation.