How Our Electronic Ignition System Works

  1. Start-Up: This is done by use of a wall switch or remote control. The system completes initial safety checks and starts the pilot gas flow when the ON command is received. After 5 seconds the hot surface igniter glows igniting the pilot flame. When the system confirms pilot flame present, the main burner gas will flow ignited by the pilot flame. 
  2. Operation: While enjoying the ambiance of your fire pit, the system is at work monitoring flame status, internal temperatures/voltages and other safety parameters. If flame loss does occur, the system will turn off all gas flow, and then restart by automatically commencing Start sequence.
  3. Shut Down: To turn OFF the fire pit simply use wall switch, remote control or whole house system.
Features: 
  • Fully Assembled- ready to install. Control components are protected within valve box.
  • Start via wall switch, remote or whole house system; auto re-light if flame is lost.
  • Ignition is complete using a robust and reliable Hot Surface igniter.
  • On/Off models: Use optional wall switch or Remote Control available.
  • High/Low Flame Control Models: Adjust high setting to low setting- ~45% turn down (Remote Control included).
  • 120vac: Standard outdoor grounded power cord- simply plug into GFCI outlet.
  • 24vac Option: Typically used poolside or with other lower voltage requirements.
  • Natural Gas or Liquid Propane: Factory built & tested for either fuel.
  • Internal temperature monitoring with overheat auto shutoff.
  • CSA Certified in US & Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.
  • Optional Controls: On/Off Remote, Timers, Power Supplies and an Emergency Shutoff.

On/Off Models: Includes the convenience and safety features- optional remote control available.

High / Low Flame Control Models: This option includes a smart remote control with 2-way communication with the fire pit. Remote allows flame height control while receiving information from fire pit to advise user of fire pit status (flashing LED).

What Our Experts Think
  • 30 × 12-Inch Configuration: The title identifies a Torpedo H-Burner system in this size; installation dimensions require separate confirmation.
  • Hot Surface Ignition: The system establishes and confirms a pilot flame before supplying gas to the main burner.
  • Automatic Relighting: Flame loss triggers gas shutoff followed by an automatic startup sequence.
  • Internal Monitoring: The system monitors flame status, internal temperatures, voltages, and other operating parameters.
  • Overheat Shutoff: Temperature monitoring includes automatic shutdown if overheating occurs.
  • Assembled Controls: The system arrives fully assembled, with control components protected inside a valve box.
  • Control Options: On/off and high/low configurations are described, with an included two-way remote for high/low models.
  • Confirm Exact Configuration: The supplied title does not identify the selected fuel, voltage, control version, or SKU.
Q&A

Q: What product is listed?
A: This is the HPC Torpedo H-Burner Hot Surface Electronic Ignition System, listed as 30 × 12 inches.

Q: Is a specific SKU provided?
A: No. A model or SKU is not supplied.

Q: What does the 30 × 12-inch measurement describe?
A: It is the size designation in the title. Detailed burner, pan, enclosure, and cutout dimensions are not provided.

Q: How does ignition work?
A: After an ON command, the system performs safety checks, supplies pilot gas, and activates the hot surface igniter. Main burner gas flows after pilot flame confirmation.

Q: What happens if the flame goes out?
A: The system shuts off gas flow and automatically begins its startup sequence to attempt relighting.

Q: Does it provide overheat protection?
A: Yes. The description includes internal temperature monitoring with automatic overheat shutoff.

Q: How can the system be turned on and off?
A: Suitable wall-switch, remote-control, or whole-house-system operation is described. Confirm the required controls and interfaces for the selected version.

Q: Does this listing include high/low flame control?
A: Both on/off and high/low versions are described. The selected configuration is not identified.

Q: How much turndown does the high/low version provide?
A: Approximately 45% turndown from high to low is stated.

Q: Is a remote control included?
A: High/low models include a two-way communicating remote with status indication. Remotes are optional for on/off models.

Q: Which electrical supply is required?
A: The description lists 120 VAC and a separate 24 VAC option. Confirm the selected version; the 120 VAC configuration uses an outdoor grounded cord connected to a GFCI outlet.

Q: Does it use natural gas or propane?
A: Factory-built versions are offered for either fuel. The fuel selected for this listing is not specified.

Q: What certification is stated?
A: The supplied description states CSA certification in the US and Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.

Q: Are heat input, gas pressure, and installation clearances provided?
A: These specifications are not supplied. Follow the exact model’s installation manual and use qualified gas and electrical installation services.

Maintenance Tips
  • Isolate Before Servicing: Shut down the system and isolate gas and electrical supplies according to the manual.
  • Allow Complete Cooling: Let the burner and surrounding components cool before inspection or cleaning.
  • Prevent Automatic Restart: Follow the service procedure so remote commands or relighting cannot activate the system during maintenance.
  • Protect the Igniter: Avoid striking, bending, or handling the hot surface igniter except as instructed.
  • Keep the Pilot Area Clear: Remove accessible debris using the manufacturer-approved method.
  • Inspect Burner Openings: Check for obstructions without enlarging or modifying openings.
  • Maintain Valve Box Access: Keep required ventilation, drainage, and service access clear.
  • Care for Optional Controls: Follow the instructions for any installed remote, timer, or control interface.
  • Inspect Electrical Components: Check for damaged wiring, cords, or plugs and maintain any required GFCI protection.
  • Arrange Qualified Gas Service: Have suspected leaks or damaged connections assessed using an approved procedure; never test with a flame.
  • Investigate Abnormal Operation: Arrange service for repeated ignition failures, unexpected shutdowns, or unusual flame behavior.