Skip to product information
1 of 10

ePower Go

Hearth Products Controls Penta 30″ High/Low Electronic Ignition System - PENTA30EI-HI/LO-120VAC

Hearth Products Controls Penta 30″ High/Low Electronic Ignition System - PENTA30EI-HI/LO-120VAC

1 Review

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price Sale price $4,254.10
Shipping calculated at checkout.
Gas Type

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

 Hearth Products Controls Penta 30″ High/Low Electronic Ignition System - PENTA30EI-HI/LO-120VAC

Introducing Our Electronic Ignition Kits

Enhance your fire pit experience with our Penta 30″ High/Low Electronic Ignition System.

  1. Start Up: This is done by use of a wall switch or remote control. When the ON command is received, the system completes initial safety checks then starts flow of pilot gas. After 5 seconds the hot surface igniter glows igniting pilot flame. When the system confirms pilot flame present, the main burner gas will flow ignited by the pilot flame. 
  2. Operation: While enjoying the ambiance of your fire pit, the system is at work monitoring flame status, internal temperatures / voltages and other safety parameters. If flame loss does occur, the system will turn off all gas flow, and then restart by automatically commencing Start sequence.
  3. Shut Down: To turn OFF the fire pit simply use wall switch, remote control or whole house system.
Features:
  • Fully Assembled- ready to install. Control components are protected within valve box.
  • Start via wall switch, remote or whole house system; auto re-light if flame is lost.
  • Ignition is complete using a robust and reliable Hot Surface igniter.
  • On/Off models: Use with optional wall switch or Remote Control available.
  • High/Low Flame Control Models: Adjust high setting to low setting- ~45% turn down (Remote Control included).
  • 120vac: Standard outdoor grounded power cord- simply plug into GFCI outlet.
  • 24vac Option: Typically used pool side or with other lower voltage requirements.
  • Natural Gas or Liquid Propane: Factory built & tested for either fuel.
  • Internal temperature monitoring with overheat auto shutoff.
  • CSA Certified in US & Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.
  • Optional Controls: On/Off Remote, Timers, Power Supplies and an Emergency Shutoff.

On/Off Models: Includes the convenience and safety features- optional remote control available.
High / Low Flame Control Models: This option includes a smart remote control with 2-way communication with the fire pit. Remote allows flame height control while receiving information from fire pit to advise user of fire pit status (flashing LED).

What Our Experts Think
  • 30-Inch Penta Configuration: The title identifies a Penta 30-inch system; exact burner, pan, and cutout dimensions require confirmation.
  • High/Low Flame Control: This HI/LO model provides approximately 45% turndown from the high setting to the low setting.
  • Two-Way Remote Included: The remote controls flame settings and receives fire pit status information through a flashing LED.
  • 120 VAC Power: This version uses an outdoor grounded power cord connected to a GFCI outlet.
  • Hot Surface Ignition: The system confirms pilot flame before supplying gas to the main burner.
  • Automatic Relighting: Flame loss triggers gas shutoff followed by an automatic startup sequence.
  • Protected Controls: The assembled system houses components within a valve box and includes internal temperature monitoring with overheat shutoff.
  • Confirm Fuel Selection: Natural gas and propane versions are described, but the supplied model reference does not identify the selected fuel.
Q&A

Q: What is the product model?
A: The model is Hearth Products Controls PENTA30EI-HI/LO-120VAC.

Q: What does the 30-inch designation describe?
A: It is the size designation in the title. Separate burner, pan, and installation dimensions are not supplied.

Q: Does this model include high/low flame control?
A: Yes. The title and HI/LO model designation explicitly identify high/low flame control.

Q: How much turndown is specified?
A: The description lists approximately 45% turndown from high to low.

Q: Is a remote control included?
A: Yes. The high/low configuration includes a two-way communicating remote.

Q: What does the remote do?
A: It controls flame settings and receives fire pit status information indicated through a flashing LED.

Q: Does this version use natural gas or propane?
A: The supplied model reference does not specify fuel. Confirm the factory-built fuel configuration before ordering.

Q: Can one unit use either fuel interchangeably?
A: The description identifies factory-built and tested versions for either fuel; interchangeable fuel use is not established.

Q: What electrical supply is required?
A: This model specifies 120 VAC with an outdoor grounded power cord connected to a GFCI outlet.

Q: Is this the 24 VAC version?
A: No. The model specifies 120 VAC; 24 VAC is described as a separate option.

Q: How does ignition work?
A: After an ON command, the system performs safety checks, supplies pilot gas, and activates the hot surface igniter. Main burner gas flows after pilot flame confirmation.

Q: What happens during flame loss or overheating?
A: Flame loss causes gas shutoff followed by an automatic restart sequence. Internal temperature monitoring also provides overheat shutoff.

Q: What certification is stated?
A: The supplied description states CSA certification in the US and Canada to ANSI Z21.97-2014 / CSA 2.41-2014 requirements.

Q: Are heat input, gas pressure, and installation clearances supplied?
A: These specifications are not provided. Follow the exact model’s installation manual and use qualified gas and electrical installation services.

Maintenance Tips
  • Isolate Before Servicing: Shut down the system and isolate gas and electrical supplies according to the manual.
  • Allow Complete Cooling: Let the burner and surrounding components cool before inspection or cleaning.
  • Prevent Automatic Restart: Follow the service procedure so remote commands or relighting cannot activate the system during maintenance.
  • Protect the Igniter: Avoid striking, bending, or handling the hot surface igniter except as instructed.
  • Keep the Pilot Area Clear: Remove accessible debris using the manufacturer-approved method.
  • Inspect Burner Openings: Check for obstructions without enlarging or modifying openings.
  • Maintain Valve Box Access: Keep required ventilation, drainage, and service access clear.
  • Care for the Remote: Keep it dry and follow the manufacturer’s battery and storage instructions.
  • Inspect Electrical Components: Check the power cord and plug for damage, and maintain GFCI protection according to its instructions.
  • Arrange Qualified Gas Service: Have suspected leaks or damaged connections assessed using an approved procedure; never test with a flame.
  • Investigate Faults Promptly: Arrange service for repeated ignition failures, remote communication problems, unexpected shutdowns, or abnormal flame behavior.